Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Is it recommended to apply H.pot test for new cables
segments after terminations or joints, however, this cable
has been tested before at the manufactor by the vendor ? or
only we can apply megger tests ?

Answer Posted / sudhakar g

Hpot is the test we can do if any cable damage happend or any leakage of current....Every cables must be tested before they sent to consumer and the test certificates also provided when ever we buy that product....Before terminated to any transformer or panels or any equipment...We have to do the megger test because if there is any cable damage while we are laying the cable....If you go for high rise buildings it is recommended use Rising main, you will tap the supply from the Rising main and main advantage is voltage drop is not occur compare to cable laying.......

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the effect of atmospheric pressure & Temp; on efficiency of motor? Why NGR(Neutral Grounding Resistor) is used in 132/11 KV Transformer & how? What is the use of Auto T/F in Grid Station?

1906


How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.

1746


Is any generator is developed which is operated with out diesal or other expensive source?

2108


how hazordious area is classified at an oil & gas plant and categorise suitable class of electric equipment in that area like induction motors, LCS, Lighting Fixtures Fluerescent/Flood lights Mercury& sodium lights, J.Bs, Power Cables etc

1845


What's mean HVF & HAF in Vacuum Circuit Breaker?

5352


How to calculate Grid rotor resistance(GRR) losses in slip ring induction motor?

4279


In Designing the rating & accessories of a MCCB how to choose the type of releases..means what is the basis for selecting, thermal magnetic, electromagnetic & microprocessr based releases

2027


what is method for testing CT

2150


i want design of D.C.MOTOR 1HP 960RPM AND 2HP 960RPM ITS URRGENT

1956


IF DISTANCE IS 100METERS B/W AMP.METER AND CURRENT TRANSFORMER WHAT WILL BE AFFECT IN ACCURACY .METER CAN SHOWING ACCURATE CURRENT OR NOT IF NOT WHAT CAN I DO TO GET 100% ACCURACY.

1839


How Can You Relate Power Engineering With Electrical Engineering?

1239


How to select batteries required for ups and the inverter if we Known load? And how AH is selected of battery?

1454


please tell me when we start motor without load in star or delta connection whose current above condition,pl write formula

2293


What cmos is and its benefits?

1219


Differentiate between ideal and non-ideal voltage sources?

1088