what happan when ac power transmitted in unity power factor

Answer Posted / rajendra

if sending end power at upf means only active power and reactive power is zero but at reciveing end side most are inductive load we need reactive power. so we never transmitted power at unity pf

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to design inductive load for 3 phase 440v and maximum 5 amps for star or delta? Can we use a 15kW, 1450rpm motor for 15kW, 960rpm apllication?If yes.how......n.if thesame motor used what`s it`s sideeefect.

2046


Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir

1433


how do you test tachos and servos

1640


what is meant by k-rating in isolation transformer?what is k9, k14 stands for?

2250


Mention the difference between Analogue and Digital circuit?

683






what is meant by flywheel and its role in retardation test

1966


do you have some of interview Questions in power and genrator section in general whith answers

1642


what is capacitor voltage transformer?? how it is different from potential transformer?

1697


why motor range is available 22kv,30kv,37kv,45kv and so on? why motor range is not available 21kv,24,25,26,27kv and so on?

2365


Classify driling machines.

704


What is a Phase shift meter? Where can I get one?

1660


what is the power factor used by the PHCN in nigeria? 2. what is the difference between an alternator and generator. 3. Generation of poweris in KV but how is transmission is in MW. 4.If the transmission of power is 20,000MW how can it be increaesed to 80,000MW

8042


As we know induction squirrel cage motor torque Directly praprortinal to applied voltage in star connection & delta also. If I connect 55KW Motor to DOL starter in load condition does motor withstand the load & what will be the current withdrawn ? motor will not fail ?

1404


Is a 300w induction motor used in a food processor as powerful as a 1000w DC motor.

1739


Does all the output contacts (N/O as well as N/C) of a Numerical relay operate when relay receives a binary input/inputs or contacts are designated to specific logic input/inputs and only these contacts operate?

1619