Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why power factor is important?

Answer Posted / sudhakar g

Power factor is imp bcoz....ex: If we have an panel that
will give the o/p of 300KW but if we dont maintain the
powerfactor by using APFCR it will give the o/p of 240KW
only....by maintain the powerfactor by using the APFCR we
can get (0.98%)....power factor means something lagging and
leading in power due to harmonics...

Is This Answer Correct ?    6 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.

1851


What is a single phase autotransformer?

1041


What is the equivalent circuit of a transformer and its vector diagram?

2641


Why IR value of the (HT cable Plus synchronous motor) is less while individually having IR values in GΩ?

1744


A 100W electric lamp is supplied from a 115V, 60HZ source. The peak instantaneous power dissipated in the lamp filament is

2329


1.what is mean by 8/20 micro sec waveshape

2168


What is the formula of frequency ?

1409


what r the safety measures in UPS ? explain all?

2171


why do we carry out winding resistance test?

2223


what is the isolation transformer. what is the isolator?

2025


Why it is possible to use PWM with a STATCOM and not with a conventional TCR based SVC

2058


11000volt DG set carnt kaise banvay

1625


During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.

1884


What are the special cables required for explosion proof wiring?

3506


in my industry we are using 3 step up transformers for induction heaters..i.e 415/580v and other are 11/440v.in power consumption does a step trnsformer makes any difference compared to step up?? plz explain

1803