At present how many HVDC lines are there in india
Answer Posted / raju mondal
At present in india there are three operating HVDC
transmission lines(not including B-to-B)
1)Chandrapur(MAHARASTRA) to Padghe(MAHARASTRA, near MUMBAI)
(1000 MW at
±500 kV DC,800km)
2)Rihand(U.P.) to dadri(U.P.near to delhi)
(1000 MW at ±500 kV DC,900km)
3)Talcher(ORISSA) to kolar(KARNATAKA)
(2500 MW,±500KV,1367km)
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
CAN CU XLPE/PVC CABLE BE USED INPLACE OF LOW NOISE SCREENED CABLE? KINDLY GIVE REASONS
2 v/500amp/hr to 1.80vpc at 20 degree celsious 2v/5ooamp/hr to 1.75 vpc at 77degree farren .this is the capacity of a battery .what is the meaning of this . can i get a detailed explenation
Dear sir, my knowledge about cable size determination is limited. Though I read examples I could not calculate the Cable size required for electric driven pump 40 KW, 380 Volt, 50 HZ, 50 meter from transformer and it is three phase star delta starting. Please help as there is no one in my surroundings to help.
hi there i am highly enthusiastic about discussing electrical concepts , and hence i wud lyk to invit al do intrested to join me at gtalk and hav a dscussun of the concepts , ad me as a freind . my email id is rakesh.2k99@gmail.com
What is current & voltage ? Voltage perform at any load without current or not?
Showing results for capital, machinery, stock,wages, carriage in words, salaries, factory rent, repairs, fuel and power, buildings, debtors, sales, purchases, creditors, return outwords, return inwords, drawings, discount allowed, discount receivable, office expenses, bills payable, bills receivable, cash in hand, cash at bank, office rent comes under debit or credit
1)Explain why the cradle guard is used on railway crossing in overhead line construction?
derive DC RMS value for half wave rectifier?
what is meant by moulded case circuit breaker ?
How many types of probe used in cro?
How may I get the maximum current capacity for a particullar size Alluminum or Copper cable if there is compulsion to use?
What tests should i carry over on a newly rewinded DC Generator with voltage rating of 38 volts and current rating of 350 amps, to certify that the machine is OK?
Give some differences between open loop and closed loop control systems.
how make megger test for control cable like 12c x 1.5mm and what it apply voltage and test timing details.
What is the differance between 2 dc motors of armature voltage 660 v and 440 v?