Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

can we charge 3 ph power transformer delta-star wound with
neutral grounded 6.6kV/415V from secondary side(415V) but
with primary(6.6kV) open by dg,what are the disadvantages or
losses.

Answer Posted / k.prakashchandra

Yes .But when you use 6.6 KV side ,you will lose earth fault
protection.There will not be any difference in losses

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are conduct on the testing in cf in ur site?

1711


what kind of quetions will ask in BHEL in interview? Plz help me?

2156


Write a note on materials used as a fuse element.

2173


How to calculate wire length,size & current? ( related to control panel)

2221


how can we calculate the ratio of caustic soda and water in lrs.

5898


Explain what are inter-poles and why they are required in a dc machine.

1140


How many devices can be connected in one zone of FACP

2360


In EHV transmission line a neutral grounding reactor is often placed at neutral point of shunt reactors. What is the recommended protection for this neutral grounding reactor? Should I use a fast closing switch to bypass neutral grounding reactor when this protection operates?

3300


different aspects of voltage stability

2127


why we use ac supply as 415 volts instead of 415 v why we cant apply 230 v for dc

2455


Give some differences between open loop and closed loop?

1165


dear all i am kumara now current working in electrical designing of control and relay panel i want learn some substaion design then any book are available. pls mention name and authour

1988


why do motors burn out? I understand why adding parallel loads to a power source means more current moves through the circuit, and can destroy circuit elements by overheating. What about when you have a vaccuum cleaner intake flush against a floor, a room fan sitting directly against a wall, or a power drill trying to drill through something too hard?

2118


If any one's require of phoenix contact like( relay , termilnal block , surge protection device ) , product please contect me 09878206357 chetan verma

2168


Define peak time.

1192