What are the voltage values for LT,HT,EHT and other
voltages??
Answer Posted / shashi nath jha
LOW TENSION (LT)= 1000 (1KV)
HIGH TENSION (HT)=11000 (11KV)
SUPER TENSION (ST)=22000-33000 (22KV-33KV)
EXTRA HIGH TENSION=33000-66000 (33KV-66KV)
EXTRA SUPER TENSION=BEYOND 132000 (<132KV)
| Is This Answer Correct ? | 45 Yes | 8 No |
Post New Answer View All Answers
for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance
what is the purpose of silicon dropper used in battery charger?
What are protections for dty type transformers
explain supply side and demand side energy management with advantages & disadvantages
What should be the Sandwitch type Al. bus bar capacity for 2 M.W.Gen. set, having continuous full load current- 3463 Amps,ambient temp.- 50 Deg. C., Required temp. raise-20 deg.C., it will run 24 hrs, 365 days on full load, required highly reliable.
difference between main metering kiosk and check metering kiosk
what ispositive, negative, zero sequence impedence?
What is process of anneling transformer core
What the formula for calculating no.of earthings & size of earth strip for 100mX90m shop.
Dear all, I'm manikandan I have done by DIPLOMA EEE from 2011 , I have 5 years of experience from Power plant instrumentation field , which one field is give long life & which one field is best ,I confused a lot and also I'm studying AMIE, can I choose which department from Section B examination? pls tell me
what are the application of over current relay?
what is relation between ct and pt ratio with multiplication factor of a energy meter? is there any other factor on which multification factor depend?
Is a 300w induction motor used in a food processor as powerful as a 1000w DC motor.
sir please send me techinical questions for junior engineer posting in bangalore railway i am diploma holder
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.