Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why do we need GC instead of HPLC? or Why do we need HPLC
instead of GC?

Answer Posted / suresh

in hplc compounds are seperate based on adsorption, in this
technique less volatile compounds are seperated, column are
made from silica.


in gc compounds are seperate based on partition, high
volatile compounds are seperated, capiilary columns are used

Is This Answer Correct ?    2 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1900


Which products will produce when acetic anhydride reacts with Ter-butanol, Sec-butanol, Iso butanol, Dimethylamine etc.

2911


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

906


inhouse product is in capsule form in combination and RLD is in tablet form then can we proceed for multimedia CDP? in inhouse capsule product disso is paddle with sinker in release media is there then RLD product in tablet form then with same as paddle with sinker we can proceed n.a.?

771


Which parameters require to do in tech transfer?

819


what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

2727


How to do regeneration of Metacarb Pb plus column?

2610


why salisylic acid not using now days for disdolution calibration?

837


What is the formula for relative diffrence for standard solution in solution stability in validation?

861


Ratio of Water and Acetonitrile(diluent) is not recommended to use in cleaning method validation,why?

3020


How you develop a method in HPLC?

2664


What is a difference between potency and purity?

1260


[3/28, 20:52] Manoj P Venkatpurwar: how many impurities require to inject in assay specificity that how we can find out? and in Rs also how?

845


when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.

2095


what is the disso medium for tropsiun chloride

2311