Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the programming languages used in dcs

Answer Posted / dipen

FOR DCS THE PROGRAMMING LANGUAGE IS CL ( CONTROL LOGIC).
DCS PROGRAMMING AND COMMUNICATION IS BASED ON THIS CL. EACH AND EVERY SECTION HAS ITS OWN CL BASED ON PROCESS REQUIREMENTS.

Is This Answer Correct ?    3 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How many are the types of instrument cables in terms of No. of pair.

2193


what is the current pay package for an instrumentation engineer having 2 years of experience in cryogenic technology???????

5033


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1467


Using your own examples solve a problem involving normal table. (experimental method and analysis)

1160


how to calibrate and troubleshooting of leveltroll?

2186


dear friends, i have seen flow as the selection critriea in presure guage (bourdon tube) and i would like to know what is the relation between flow and performance of pressure guage other parameters i found in the data sheet are pressure max. 1ksc temperature max. - 50 deg c line size - 80NB operating range - 1ksc pr. guage range - 0-2 ksc thank u,

2168


If fire would be inside the plant which fire detector is to detected the fire.

1606


Where is wet leg is used?

1061


in sulfur process what is material of impulse line we use to connect with transmitter ? and does teflon affected by sulfur?

2270


what deference between panel earth and systemearth

2326


hi,i am doing 3 year in electronic and instrumentation engineering. what type of aptitude questions will be asked in a core industries and how can i improve my skills in instrumentation?

2102


what is difference between HOT permit and cold permit

2197


What is Cavitation in a control valve?

2063


How earthing can be checked????

2406


please tell no. & add. of consultancy who recruit me in power plant as instrumen engg. present i m working in power plant as ass.t instrument engg. thanku mahesh 09226562826

2088