Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

SUPPOSE A CIRCUIT BREAKER HAS TRIPPED THE THE LINE WHEN A
FAULT OCCUR ON IT.NOW WHEN THE FAULT HAS BEEN CLEARED, HOW
THE CIRCUIT BREAKER WILL CLOSE AUTOMATICALLY NOT MANUALLY.

Answer Posted / gavin

Circuit breaker miniture as found in a consumer unit or
air as in a switch panel. MCB will not auto reclose as per
BS7671.
ACB will auto reclose using shunt coil but not if earth
fault is not reset first manually

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Zone of protection and tripping scheme of arc protection relay.

1929


i want bhel placement paper for electrical if anybody having pl send to my id kavitha867@myway.com immediately

2031


Why are the cores of large transformers built up of circular transactions ?

2061


how to deside the capacity of chock for drive?

2106


oltc of a transformer, how it works? and what are the equipment consist of describe briefly?

2068


If we have use two power cable for incomer, that time how many use cbct for earth leakage protection? 1 or 2 if 1 way? If 2 way?

2155


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2202


what is a reactive power? what is the relation with power factor?

2251


What is ramp signal?

1163


size of condotory fron voltage level

2261


I completed my BE EEE degree 2006 .... which license should i apply .... ?????

1777


what can be the causes of capacitor start motor having a higher current that its actual