why 4ma show higher zero ?
i have transmiter flow renge 0-1000 m3/h but 4 ma show in
monitoring 200 m3/h and 20 ma show 1000 m3/h i want when 4ma
show 0 m3/h and 20ma 1000m3/h
Answer Posted / dinesh priyadarshi
1) Set LRV & URV by HART
2) set zero at your desire value by HART
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is surge and how is it prevented, what is the purpose of bypass valve across AS valve.
how can use ram
What are different type of instrument cable
What are the materials available to prepare individually for competetive exams in Instrumentation field? Plz reply...
how to connect transmitter measuring sulfur process? 1-by using long impulse line or 2- by using coated short impulse line
what can of fault ofently come in vibration mesurement?
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
How is automatic reference junction compensation carried out in temperature recorders?
Hi i am aneesh, done btech in applied electronics & instrumentatiin. And then i took mba in finance & marketing.After that i got placement in finance co and worked there for 3.5 yrs.Now i wanted to come back to engineering job.But without engg experience, i may not able to find an opening.i have done a course related to flow meters and ite calibrations. Kindly suggest where should i try to get a job?
How to calibrate Field bus transmitter? procedure ?
I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?
what is temperature compensation?
Dear Friends, we are planning to design Power distribution and Fiber optic in the same cabinet.Like Front side Fiber optic and Rear side Power distribution.Is it any possibility of problem occurs like interference etc? Your answer is highly appreciate.
what is IEC code in cables & how to selecting cables?
Which Signal hart communicator work? If there any signal change when hart connect while transmitter in line ?