Answer Posted / kunal
first of all open the two nos screw than check interlock if
bypassed, than PULL the card.
so simple.
| Is This Answer Correct ? | 8 Yes | 1 No |
Post New Answer View All Answers
Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer
all questions related to instrument technician in any offshore oil and gas company.
Reason for capillary type dp level transmitter fluctuation
Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .
Can anyone convert a 5/2 way or 3/2 way valve into an ISO valve?
Please any one can provide latest aptitude test,technical test and interview questions for tata consulting engineering (TCE) i need it asap thanks in advance
I have got a call of IOCL interview for projects having 2yrs experience. What sort of questions should I expect in the interview?
What are continuances of connecting earthing and shield of branch cables (instrument to Junction box), at the same earthing pot provided on JB? Is it ok, or may produce some problem?
why we r opening HOT BYPASS valve during startup of a compressor?
1.what is controller proportional gain 2.what is the controller intergral action time. 3.A proportional plus derivative controller that has a proportional band of 20% and a derivative action time of 0.1 minutes. Construct the shape of the output waveform for the triangular input if the input rises and falls at the rate of 4 units per minute.
on interface level transmitter model(RTG3302-EMERSON) What is threshold valve how can we select correct threshold value T1,T2,T3,T4 When interface water & hydro carbon
Is there any relation between Artificial Intelligence and Instrumentation?
please can any one tell me clearly about pid tuning i am confusing about this .how to tune pid easly?
State four different types of flow measurement, for gas flow measurement MMSCFD is the common unit expand the unit and specify significance of word S in the unit.
how to do dynolab wind speed sensor loop test, how to simulate value,i have simulate mA 4-20mA but not responding in DCS faceplate, please kindly advice me any one.