What is the d/f between DOL & star delta starter & automatic
star delta starter?
Answer Posted / sanjeev
in dol starter starting torque is high.which is on light load.it is connectrd direct to line and used below 5hp.
in star-delta starter starting torque is 60% and it reduced to 1/3and its then connected to delta.this starter is used above 5hp.
| Is This Answer Correct ? | 2 Yes | 2 No |
Post New Answer View All Answers
how to calculate the cable current ratingand and how much of distance the rating will be ok will the distance is incresed what the action we take
if a 3phase 100kva distribution transformer , 400 v,50 hz, 4-wire system is loaded at 160 k.w mostly 1-phase Lighting & Airconditioning split a.c load what will be the net effect on the power system in terms of voltage, powerfactor, current , efficiency of xformer
What is the name of the winding to which supply is given?
explain with diagram how to protect transformers and substations from over current with help of CT's?
Give details of your interested designation, the post you are interested to serve the company better and explain why you think you can serve the company better in such position if employed?
If i am running of spindle at 2000rpm ,but How to spindle stop at the second I am resetting the machine in CNC machines
How can get elongation of 2 k.G aluminium, if elongated aluminium dia is 2.5 mm?
Dyn1 transformer vector group testing how to do
Why does an induction generator is preffered as compared to synchronous generator in especially a wind energy power production project?
1. The DC generaror,s induced output emf is connected with a DC motor(as load). when increasing the load of the motor by using brake drum or any way. what are the parameters will changes in both motor and generator(voltage, current, resistance, frequency, speed, torque, power, flux etc...) 2. Similarly for AC generator and AC motor 3. similarly if using DC batteries instead of DC generator, What happens?
what is the series parallel connection of capacitors? and how can we use these application in three phase motors for controlling torque?
HOW TO DESIGN THE body EARTH cable(Copper Conductor) size for 60KVA UPS?
A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE
How to know vacuum in vacuum cylinder of breaker in working condition
How does a tertiary winding filter harmonic(espcially 3rd one) from entering into load system?