Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Write the formula for Fault MVA, Fault current, Base MVA.

Answer Posted / mak

The fault current of a power transformer will depend on the following;
Transformer Rating (in KVA/MVA)
per unit impedence of the transformer (%p.u.)
line/phase Voltage (VL/VP)
the following formula can be used to find the fault current on the secondary side of a transformer
Fault Current = Transformer Rating /(per unit impedance x phase voltage)

The Values of Transformer Rating, per unit impedance & phase/line voltage will usually be mentioned on the transformer rating plate / data sheet
As an example a 500kVA, 11kV/400V/3-Phase/50Hz transformer with 5% p.u impendence will have the following fault levels on the secondary side

Fault level = 500/(5%)=10000kVA


Fault current = 500/(5% x 400 x 1.732) = 14.4 kA

Remember to use 3phase voltage!

Is This Answer Correct ?    3 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the difference between single ratio, multiple core and multiple ratio, multiple core ? please explain.

2146


how to deside the capacity of chock for drive?

2000


is it possible to have dc motors on single chip

1773


Describe Non I.S. Earth System and why is it used?

1725


Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this

1694


What is the comparison between 30mA DP RCCB and 100mA DP RCCB and can replace it against 63A MCB

1533


In constant power region of 3-phase IM torque-speed characteristics, if frequency increases flux A does not alter B decreases C increases D none of above

2182


WHAT IS ELECTRICAL MAINTAINTENCE ?

2001


What is the effect of solar radiation on the design of an Isolated Phase Busduct?

2295


where reactive power is used

1992


Why MCCB is Getting tripped sometimes when there is no load in the Midnight ?

1915


Operation of isolators.

1828


How to address the servo drive for motor

1948


Why are the laminations insulated from each other?

1097


what is distribution board?

2259