Why we have use 3 & 1/2 core cable use for general electrical supply arrangement
Answer Posted / mansingh
1/2 CORE USED FOR NEUTRAL CONNECTION. IF ELECTRICAL LOAD IS
BALANCED THEN NO LOAD WILL BE ON NEUTRAL, IF LOAD IS
UNBALANCED THEN UNBALANCED LOAD WILL GOES THROUGH
NEUTRAL.SO FIRST WE SEE THAT LOAD IS BALANCED IN PHASES
THEN IN THIS CONDITION NO CURRENT WILL FLOW THROUGH
NEUTRAL,SO NOT REQUIRED FULL CORE.
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
what is the significance of tan&delta and how it performed in power transformer
two phases with neutral supply can be taken in 3C X 10 sq.mm cable .
what is the safety of voltage power transformer(2250KVA0
What is the difference between circuit breaker and isolator
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
What is tan delta & PPM in transformer? and whats its IS value?
what is the meaning of osr in transformer.
i installed 100kva ups. what KVA genset they should provid in input side? plz any update formula or ans with reason.
why do we carry out winding resistance test?
What range of speed can you get with the field control method of speed control of d.c. Shunt motor?
What is the formula to calculate a three phase alternator
how to decide choke rating for drive?
what happens to the water pump if ground water level is slowly decreasing?our water pump is varying from no-load full-load due to this problem
A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.
I am going to appear for the RRB Chennai Section Engineer online exam. Please send me the question papers from 2001 to date to my mail id:upendrakrishna20@gmail.com,plz send me ,or send any other rrb papers plzzzzzzzzzzzzzzzzzz