Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is D check in a Diesel generator for 1000kva DG

Answer Posted / shubham mathur

"A" - Daily Checks
"B" - 300 Hrs or 6 Months
"C" - 600 Hrs or 12 Months
"D" - 1200 Hrs or 24 Months

and Sanath Shetty is correct

D-check (Every 3000- 5000 Hrs.)
1. Complete DG set should be dismental.
2. Turbo charger service
3. Injector Pin service
4. Cylinder Head service
5. PT Pump sevice &
6. Repeat the B-Check process.

If your DG set running hours more than 10,000 then in D-
Check You should
1. Change Piston Bearing,
2. Change nozels,
3. Piston Cylinder also need to be change.
4. Change Canopy filter if require
5. Check polution level

Is This Answer Correct ?    9 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?

2004


what is the difference between gas group b and gas group c electrical equipment construction wise?

1861


Why are iron cores in transformers made laminated?

1109


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

1834


how the phase convertor changes the no. of phases

1989


What is the maximum and minimum rating of UPS?

1491


STATE USE OF ARC RUNNERS & SPLITTERS ?

1944


diff b/w elcb and rccb

2289


Is there any rule to select the voltage of motor based on KW rating? What is the rating above which lt motor becomes the HT motor?.

1711


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

797


Why 15Amp. MCB is suitable to carry load of 1.5Ton Ac please Explain?

2162


What is dc current source? Differentiate between ideal and non ideal current sources?

1463


I am going to appear RRB Sr. Section Engineer Exam, Electrical. Can you send me previous year questions of RRB Electrical engineer. specially Section Engineer questions. my email id is likerahulworld@gmail.com

1798


how can i determine the KVA/MVA rating of transformer precisely?? is there any standard test?????

2388


Tell me all plants load factors i.e which plant operating on which load?