I am having 120KVA UPS,which is connected to DG & normal
power. What is the power drawn by this system when system
is running on DG ????
Answer Posted / v.venkata ramana
power drawn to the system 167.5 amps
| Is This Answer Correct ? | 1 Yes | 2 No |
Post New Answer View All Answers
how to calulate short circuit current for the following: 1.cable connecting 11KV of 22KV/11KV transformer to 11Kv of 11KV/415V transformer 2.what cable size should i use.
What is synchro?
How we select the vector group of 3phase power transformer?
In how we connect watt meter for open & short circuit test of a single phase transformer.
What is minimum phase system?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Explain what is electric traction? Explain few advantages of electric traction system?
how electical engineer is related to apsrtc (general) post? if they ask a question in interview as why did u choose this job what shd be answer
what happen when increase or decrease size of lamp,light.glass.
Why the moulded plug comes with domestic appliances instead of assembled plug like anchor, Vinay 5/15 A.
What OPGW is better than Microwave or PLCC???
please suggest some good universities with low cost iam in totally full confusion so please help me my profile gre 283 and ielts 5.5
what is the efficiency of thyristor
WE ARE PLACE A NEW 75 KW MOTOR FOR JPF.IT IS CONNECTED IN M.C.C. WHEN WE ARE STARTING M.C.C.INCOMER IS TRIPPED.THEN WE ARE CONNECTED IN P.C.C WITH A MM30 RELAY PROTECTION THEN WE ARE STARTED MOTOR WILL RUN SMOOTHLY.
I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?