Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What happens if you give supply to the rotor of three phase
induction motor?

Answer Posted / vibhakar

there are two types of IM one is squirrel cage and slip ring induction motors.In squirrel cage rotor windings are short circuited with end rings where we cant give supply therefore this type of motor has more efficiency because losses due to slip rings and brush assembly is less...but in case of slip ring IM in order to increase torque, resistance is added through slip ring assembly

we can give 3 phase supply to rotor and they are callled as rotor fed IM

Is This Answer Correct ?    3 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHICH SIZE A.B.CABLE IS USED FOR 11KV.

2133


what is doubling factor in making current of a breaker?

2008


Either It Possible a dc Motor to Run On Ac Drive [ Ex : ACS 800 , Yaskawa F7 ] If it is Possible How Pls Inform Me dinesh_elect_eng@yahoo.com

1921


Why is a plain induction motor unsuitable for wide speed control?

2227


Can we use a absolute encoder to show rpm of a motor ? what about the condition when power is off ? what is difference if a incremental one is used ?abanirout@gmail.com

1971


I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?

1686


why transformer ratings in kva? & DG ratings in kva? & Motor ratings in kw/HP?

1450


Explain forward resistance, static resistance and dynamic resistance of a pn junction diode.

1114


i have a 1500kVA transformer what is the kWH meter i need to use?

1710


What are the specifications for conducting earth leakage test as per IEC standard?

1994


why there using acb enclosure in big buildings

2037


High speed earth switch operation with diagram

2411


i m doing DEEE in part time,can i join regular cources in BE,,IF i join what the cources can i select like (civil,ece,IT) ,,kindly advice

2058


What will happen to the protection and metering, if the polarity of a single or two PT/PTs in three phase system is reversed? Please provide reference if any.

2131


why use phase displacement in transformer.and effect of phase displacement on transformer

2811