I do wonder why current is present in neutral wire?i check
single phase lead current feeding air conditioner...on its
phase its current was 10A while same was 10A in neutral...as
we know in neutral voltage is zero so if voltage is zero
then how current appears on amp meter?
my second observation is (just imagination)when I touch
phase wire it give me shock but when i touch neutral nothing
happens although as above its carrying current(amps)
third but with same logic...as in simple Alternate current
sine curve there is + and there is negative peak.means every
time phase changing so how come every time same phase and
same neutral stand
(pardon for english mistakes)
Answer Posted / puneeth kumar
In neutral current should flow, because it is return path. It
is not giving shock or while checking in tester it will not
glow, because current always choose the least path and neutral
is earthed and our body as about 1000ohms (as per IEEE 80).
In neutral always voltage will be zero only, since it will
connected to ground in star point of transformer. Positive and
negative waves will be appearing in phase only.
Check in 2 phase, you will get 2 waves.
Is This Answer Correct ? | 8 Yes | 0 No |
Post New Answer View All Answers
what material is the electrical housing wire made of? is there any difference for the telephone lines?
Define conversion efficiency of a power amplifier. What is its value for class c power amplifier?
What is meant by analogous system?
Is it true that in the 3 phase transformer, the limbs of the core are at 45 dgrees to each other. if true, why?
what is the purpose that we use PLC system in power system
On a 3 winding transformer YNynd11, how do you apply REF protection to the Delta tertiary winding that is supplying auxiliaries to a substation?
i want to know that how the height of Ct ,cvt ,LA calculated on the basis of creepage distance
Why computer humming sound occurred in ht transmission line?
what is mean by restructuring power system?
I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?
How do you compute voltage drop and cable size over distance?
how to select the double earth conductor if 21A full load?
What is the formulae of Megger value for a A.C.Motor
What do you mean by passive circuit elements and why these are called passive?
what is settable hystersis protection? If any body knows plz kindly post the answer..