Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

I have running 4 generator in paralel.All generators
Voltages is same(470 V),KW also same (100 KW) but only No2
generator Amper is high than another generators.
DG No:1,3,4 470V,100KW, 150 A
DG No:2 470V,100KW,400 A

Answer Posted / ruslan

Yes My friend it is possible.All meters are in good
condition.I also surprised.

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

can the measured percentage error during calibration of single phase energy meter be negative?

2347


There are different classes of protections in power plants.class a,b,c are clear..is there any class d and e r there..and elaborate class b protection.

2041


why occ characteristics of generator is also called as magnatization characteristics ?

2015


can anybody tell me that for p.f. Improvment we use capacitor banks but how to decide its capacitance. As we all know how to calculate kvar but what abt capacitance value

1809


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1808


Briefly describe means used by electricity suppliers to influence the flow of active and reactive power in power networks (one for each type)?

1900


how to test power transformer.YNd11

1511


What the difference between three phase contactor (coil 110vac) & three phase SSR (control voltage 110Vac)? May I use contactor in place of SSR?

2108


What is method of calculating the fault current for a MDB, 50KW, 3PH, 415V, 50HZ?

2092


How you calculating the 30 Hp 3 phase AC motor of power what size of cable is used for this motor?

1617


model question paper for supervisor trainee

1984


Explain (in simple ) - root mean square. whats its role in electrical fundamandal.where its used

2322


why we testing the core balance of the transformer before comissioning?

2108


Difference between transition and diffusion capacitance

2919


we have 15 ampere variyac but we want 30 ampere variyac what we do

1865