Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

there is a # KVA Transformer of 11 KV/440V, in simple(not use formuia) how can you calculate it's HT & LT side current.

Answer Posted / guest

HT side current = #/20 LT side current =#+#/3 ie 100KVA 11KV/440V transformer it's HT side current = 100/20=5 amps LT side current=100+100/3=133 amps. this is approximatelly figure(answer), Line man of Power Distribution Company fallow this method .

Is This Answer Correct ?    8 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What should be the magnetic balance test values for a 3 phase delta/star connected single primary dual secondary winding transformer (90 MVA / 2 X 45 MVA TRANSFORMER)

1847


WHY EARTHING NOT NEEDED IN BATTERY IN SUBSTATION

1909


What is the most important precaution in any experiment with d.c. Shunt motor?

1203


Make a list observation on Transformer?

2377


Why do power lines not short out when they fall into water?

1931


Can the output voltage of a rectifier be greater than the input AC voltage without the use of any voltage multiplier in the circuit??please provide the explanation too..

2059


What is tranformer differtial?

1956


Would you recommend to replace all oil filled cables with xlpe cable for hv transmission with the current technolgy for xlpe cable?

1430


What is the difference IN MCCB's between thermal magnetic and electronic tripping system ?

1979


The windings of a transformer are divided into several coils, because?

1216


Two electric lamps 40 W, 220 V each are connected in series across 220 V. What is the power consumed by the connection?

1358


THERMAL CAPACITANCE IS MEASURED IN..................................................

2087


Where voltage are high and current to be interrupted is low the breaker preferred is:

2226


I want to replace the 3 KW DC motor with AC motor so what should be the rating of AC motor? Details Of DC motor to be changed with AC are - Kw - 3, Vf - 310, If - 0.15, Va - 400, Ia - 13, RPM - 2400

1774


can someone explain that how the speed of the protection system affects the fault level calculation?

2014