what happens when ac supply is given to D.C motor.
Answer Posted / swarupa
In ac supply the magnitude and direction of voltage or
current changes for every half cycles so the dc motor may run
but in very low speed due to less torque develop & also due
to inertia.If it is run continue the frequency losses may
increase due to high heat.The efficiency poor.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
Calculate torque developed by the 3-phase, 5 H.P., 4 pole induction motor runs at 1500 rpm A 23 N-m B 21 N-m C 10 N-m D 0 N-m
A well system is when , no. of bus bar is less or more. Tell me the concept of it.
If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..
What are the different sign conventions used in electric circuits?
What is the formula for calculating the Instantaneous Short Circuit & overcurrent for any breaker
hi every body i am master student in control engineering and my project is slip control in trains i assumed a Dc motore as traction motor but i don't have characteristics of this kind of motor that is used in train. i want from every body if he or she has the characteristics or information about Dc motor that is used in train give me those information or technical characteristics .
What are the types of power in electrical power?
what is earth resistance? how to measured? and give values at power station and mcc area?
can any one know is sbi interview based on merit or based on roll number
how to avoid electrical shock how capacitor store charges wat are the speed control of induction motors state faradays law flemings left hand rule what is rotary converter wat is transmission and distribution what are the sources of energy abrevation of acb,vcb,sf6,igbt what is output equation of transformer which test copper iron and iron loss are calculated what is eddy current draw a single line diagram (10 marks) draw direct online starter(10 marks)
please send me jindal previous aptitude and technical question and answer.my email id is deep_raj@live.com
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
I have 440v power coming to facility,( not being used ) can I buy large generator, (gas) to sell power back to electrical co.
How much no load current of synchronous motor
What is the drawback of static coefficients?