what is the difference between electrical & electronics
Answer Posted / priya
electrical=operated in high voltage low frequency
electronics=operated in low voltage high frequency
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is the relative size of single and three phase?
WHAT IS SPEC OF CLEANROOM MOTOR AND LIGHT FITTINGS?
As i want some model question paper in basic computer science and history please send me immediately sir
what does mean of RCT and STR in diffrential CT?
Is there a possibility to use such a treshold voltage for the NMOS part of a CMOS circuit that during the switching it will start conducting only after the PMOS part will be already closed, by this eliminating the leakedge current? Please note, I'm not asking about the well bias in standby mode, but about the "antileakedge" measures during normal operation.
How Can you do Maintenance of ACB of 2000Amperes
can we start slipring motor on star delta like we start induction motor ? if yes where will we connect ?
hey guys help me out.....what are the industrial uses/functions of nozzles in industries
what is the minimum winding resistance of 30hp compressor, to run or to switch on
Why is remote backup preferred to local backup?
when ac current flows thru d coil of a contactr,it energizes,magnetic field attracts d contact of the coil...nw wont dt ac current in d contct induce current back on to d coil thru mutual inductance leading to high currnt in d coil
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...
WE know that for Inductor X=2pifL,In DC f=0,then X=0 so,V=IX=0;But In the DC excitation of rotor of AC generator,DC motor field coil which coils are inductor so why does not applying DC voltage short the rotor coil of AC generator and field coil of motor?If it would then DC source might be damaged but it is not happened. Why does the strand conductor of Electrical power transmission line make twist?
PLZ EXPLIN ABOUT CLASS PS CLASS CT .WHY THEY R DESINED AND FOR WHAT PURPOSE?WHY OTHER CT CANT BE USED AS PS CLASS CT? EXPLAIN IN SIMPLE LAUNGAGE IF POSSIBLE PLZ GIVE CIRCIT DIAGRAM?EMAIL-RAJ_SINGH_0376@SIFY.COM
what is meant by CT`s saturation ? Can we use Metering CT`s with Protetection CT`s ?