Which power will flow first if we switch on a motor? Active or
Reactive? How?
Answer Posted / rishi
reactive power will flow first because as we have generally the motor electrical equivalent circuit composed of series resistors and inductance.
now if in any such circuit if current is to flow then it must charge the inductors first and then current will flow through resistors. hence this will lead to reactive power flow at the very first instant of machine switching.
| Is This Answer Correct ? | 5 Yes | 1 No |
Post New Answer View All Answers
Write down the design procedure of commutaj.
hi, i have 3x200KVA and 2 x 80KVA UPS with battery bank of 150AH 68Nos. and 100AH 204Nos., i need to install AC either ductable or PAC type, so can you help me to calculate heat load and capacity of the AC to install.
What is turn ratio of a transformer?
How many types of electric motors are there?
State ohm’s law?
What is effect of harmonic current (Draw by VFD) on power system/ electrical Equipments ?
What is advantages of VSCF wind electrical system?
Efficient electrical earthing in hard rock area
1- What is the Polarization Index number be good for 15KV 3c#500MCM electrical cable? 2- Can I use the IEEE Std 43-2000 to perfom the PI test? Thanks
for hipot test on 33kV busbar, we will test on 70 kV or 56kV, what is the acceptable leackage current?
Why it is necessary to isolate fire fighting when you are taking shutdown for lv board.
What is main cause of cable's terminal point burned in Lug on high temperature although lug and cable selection is ok as per stantard and also tightness is ok as per situation. so please take in deep and tell correct answer thanku.
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
How to calculate that clean water supply in one Day from 150 KLD STP?
What is method of calculating the fault current for a MDB, 50KW, 3PH, 415V, 50HZ?