Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

3phase motor 400v (induction) A.C 4kw company design 1400rpm
but our requirement 2000rpm possible? attached any instrument.
reply fast! contact 03343262442

Answer Posted / michael

i dont think it is possible,
because i know 1400rpm is
the rated speed or full load speed,
even we vary the frequency still
it will overload because the
2000rpm is higher than the
full load rpm.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?

1648


can we synchronize star system generators with delta system generators?

2048


what about the power of wattmeter at starting and loding?

2089


Importance of fault current in power transformers and how to monitor the same? How is it different from winding temperature?

1829


describe the Tranformer testing procedure

1871


Define filter?

1113


can I improve the furnace power factor (10 mva transformer) by adding a capacitor bank before the transformer.Does system power factor vary a lot with the furnace PF?

2040


How servo stabilizer works.

2113


what is the difference b/w UHVDC and HVDC(LIGHT)?

6740


Why do we need interlocking in a HT metering or Ring main unit switchgear?

2014


If symmetrical fault occurs at the terminal of a synchronous motor then how the motor will act...explain it..

2133


What happen when change order of CT in GIS feeder?

1647


How can maintain our H.T. motors used in cement plant. please send me procedure.

5145


Maintenance of transformer???

2255


why can we use cosine wave instead of sine in ac supply as both have same rms vale and ripple factor

2551