Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between megger and earth tester?

Answer Posted / saumya ranjan lenka

<1>Megger=Meggar megger means insulation resistance(IR VALUES) of any cable ,wire bus bar etc .ITS UNIT IS OHM
<2>
It only measure earth resistance of pit.ITS UNIT IS OHM.
It has two electrode (i.e potential electrode and current electrode) with respect to earth plate under test. The potential electrode will fixed 15mtr from earth plate under test and current electrode 30mtr from earth plate under test.
<3> IF WE ROTATE THE HANDLE OF EARTH TESTER IN OPEN CONDITION THEN THE READING WILL BE 0 OHMS. BUT MEGGER WILL SHOWS INFINITE OHMS.
<4 >MEGGER HAS THREE TERMINALS <i>LINE
<ii> GUARD
<iii>EARTH
<5>EARTH TESTER HAS THREE TERMINAL <i>E(earth plate under test) <ii>P(potential electrode ) <iii>C( current electrode)
BY ER.SAUMYA RANJAN LENKA, STERLING AND WILSON LTD ,DSP SITE WEST BENGAL

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the exact formula for one weber of magnetic flux?

2139


Why using synchronising methed in DG's sets?

2216


What should be setting for alarm,tripping and cooling fan on for power transformer's oil temp. and winding temp. indicator?

1945


What is purpose of reactor?.What is different between line and bus reactor?

1953


At what speed 1 HP motor can run an electric car of weighing 400 kg?

1584


what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....

9246


How to design a Unit auxiliary transformer for a power house having a unit of 65 MW and Generating voltage of 11 KV and Secondary voltage of 433V

2138


Explain about 3 phase motor fault current calculation with examples?

2953


Either the Armoured Earthing strip of HT 3 core cable have to pass through CB CT or not , why ???

2091


1)how to reduce the value of tan delta of trasformer and CB,bushing,CT&PT,CVT ? 2)how to reduce the resistance of CB contact and its operating time? 3)plz.....send me the project report on conditioning and monitoring of substation equipment on my email id (gusaiyogendra03@gmail.com)

2303


can you plz send l&t aptitude questions if available its urgent plz plz plz

2121


at what basis/standard we have to arrive the current density of aluminium/ copper in busbar?

2129


Dear Brother can u tell the proper size selection of cable & the fault level calculation of braker, busbar etc. pls mail me at azeemk30@gmail.com

1937


what is the difference between linear choke and suction choke?

2743


What is the function of auadag in a cro?

1131