Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what happan when ac power transmitted in unity power factor

Answer Posted / karthik

i dnt think transmitting at unity pf. we can produce
voltage in that we normelly used to gen at 0.9 leading pf.
we couldnt go beyond this limit bcz of over rotor heating.
if we use this power for more number of motors and
lightings which is having low power factor the resultant
current drawn from the gen station ll be lagging only..
power factor purely depends on load only. at gen station we
can go upto alternator allowed range of leading pf..


if we consider this question as in the distribution station
if we try to deliver power at unity pf we may fail to judge
the load pf at each instant.. it may vary time to time..

even we further concentrate and done it we can minimise the
losses in line and billing of industry may reduce bcz of
UPF @ they r charged by KVAh tariffs...

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is critical disruptive voltage?

1324


how to electronic energy metter failed in electomagnectic fild passing in the metter and which thing to defect more on metter.

1983


In a large office how do we calculate required number of light fittings, assuming fittings are 4x18W or 2x36W fluorescent fitting ?

1882


we all know voltage is a force(emf), and the force always devides if 2 or more than2 loads are there but why does the voltage remains same is parallel, it must devide na ???

1998


How delta connection in the primary of distribution transformer reduces harmonics?how delta connections reduces harmonics?Please answer me...Hope that question is correct.

2225


How much no load current of synchronous motor

2104


why it is not advisable to run low rating (19KVA) DG sets in parallel for long durations even though they are provided with droop ckts (QDC)

1912


what is droop control?

2188


How to calculate flow of water delivered by pump when pressure & size of pipe line is given

2308


where is the need for short circuit test for 3 see is required and why? can you explain in brief with application

1962


I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.

1877


What are the section criteria for cables. Now everywhere XLPE power cable is used or PVC is also used?.

1678


What will be the size of copper cable (each for 3 phase and 1 neutral) from Service connection Kit-Kat to Panel Board (i.e. to main switch) for a 6 pole 3-phase AC induction motor of 200 H.P. capacity? Amp-255 A, Frequency:- 1450 rpm.

1980


thyristor controlled APFC panel design parameter?

1795


battery capacity use of made?

2549