Answer Posted / chennurupavanireddy
we can improve power factor by connecting capacitors in
parallel with the circuits so that they compensate lagging
components and improves the power factor there by the
efficiency of the circuit increases.
| Is This Answer Correct ? | 9 Yes | 3 No |
Post New Answer View All Answers
Please explain, how to test vector group of tranformer(Delta y1) . Thank
what is difference between cpp electrical system and refinery electrical system
Explain what cmos is and its benefits?
how to calculate single phase motor efficiency ?
What are the different types of dams?
In constant power region of 3-phase IM torque-speed characteristics, if frequency increases slip A does not alter B decreases C increases D none of above
hi frnz,can somebody give me any project work? i am a 2nd year student & interested in practical works...plz give me some projects
I'm looking for a mnaual set for a Teradyne J750. Softcopy would be preferred but I'll take what I can get.
WHY BREAKER ARE USED IN SUBSTATIONS?
What is called grain-oriented laminations?
If you have an earth with pilecap then your resistance is really low. why and how?
Why need 3phase machine double earthing?
if field breaker of generator is closed prior to its rated speed on a power generating unit. what will be the effect on generator, unit transformer and starting transformer.
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
ii) A shunt motor supplied at 230V, runs at 900 rpm when the current is 30A. The resistance of the armature is 0.4 ohms. Calculate the resistance required in series with the armature to reduce the speed to 600 rpm, assuming that the armature current is then 20A. [12]