Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is difference between co-generation and captive power
plant?

Answer Posted / subbu

Captive power plant means generating power that can be
utilizse home load and also can be export to GRID with out
utilizse the steam.

Co-generation plant means generating power that can be
utlisize home load, can be export to GRID and also
utlisizing the generated steam

Is This Answer Correct ?    13 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How u can give the overload setting to any motor protection relay for a HT motors with formula and Example?

2132


what is mind in cable

1999


what is excitation/

2144


During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.

1884


draw the full wave and half wave circuit of 3 phase system and inverter circuit used in upsĀ 

2343


a 100mva,400/200v transformer has leakage impdce of 10% draws a steady state line currentof---------------

1855


How to Make relay co ordination chart for a Electrical power distribution of a plant

3766


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The slip when motor stalls is A 1 B 0 C 13.33% D 10.33%

1850


why high speed tripping relay will be used in tripping circuit why not normal relay

1294


What is the difference between acs 550 & acs 850

5744


How many capacitors using in LT panel as per Govt rules?

1913


How does a battary stores charge in it? please explain in simple manner and in detail.thanks

1923


what is the condition for YnD11

2498


we have two motors 1250kW,6.6kV to be coupled on the same shaft ,so please provide assistance for their synchronisation.

2020


what are factors to be consider in electrical installation like load factor,diversity factor .....

1762