Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


1. What means HART communicator / where it is used /
how to use it?
2. Types of Thermocouples and its temperature ranges /
output of thermocouple?
3. Types of RTDs and its temperature ranges / output
of RTD?
4. Idea about Temperature Transmitters?
5. Difference between Analog and Digital signals?
6. Difference between “2 wire” and “4 wire” system /
instruments?
7. Difference between “Potential” and “Potential free”
contact?
8. Types of flow meters / transmitters?
9. Types of level transmitters?
10. Difference between “Power/Control” cable
and “Instrument” cable?
11. What means “shield” and “screen” in cables / how it
is useful?
12. Draw a schematic of closed loop circuit of flow /
level / pressure / temperature?
13. Idea about calibration of Control valve /
positioned / I/P?
14. How to bypass a digital/analog signal in PLC/DCS by
hardwire and software?



Answer Posted / manish kumar singh

Ans.1-
HART
The HART system (and its associated protocol) was originally developed by
Rosemount and is regarded as an open standard, available to all manufacturers. Its
main advantage is that it enables the retention of the existing 4-20mA
instrumentation cabling whilst using, simultaneously, the same wires to carry
digital information superimposed on the analog signal.
HART is a hybrid analog and digital system, as opposed to most field bus systems,
that are purely digital. It uses a Frequency Shift Keying (FSK) technique based on
the Bell 202 standard. Two individual frequencies of 1200 and 2200 Hz,
representing digits ‘1’ and ‘0’ respectively, are used. The average value of the
1200/2400Hz sine wave superimposed on

Is This Answer Correct ?    15 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the application of bernoulli’s theorem?

1199


need instrumentation job completed 1 year trainee ship in mnc pesticide company. now in search of job

1946


Can u tell me the principle of the tc,rtd,level switch,pressure switch ,transmitter(pr flow level temp.),vibration...plz

2097


can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.

2318


why fuse block is not used for AI signal?

1950


How to calibrate an pressure gauge with yantrika test bench?

2945


how to relay switch sense the fault?

2661


Can anybody please let me know Orifice plate sizing calculation formula and step by step procedure

2031


How d.p. Transmitter can be applied to open tank?

1175


What care will you take in the installation of control valves,SCADA,DCS and FOC in Oil and Gas Project?

2170


when a magnet is heated?

2034


IN CONTROL VALVE SPECIFICATIONS GENERALLY TERM " DE- 200" ."DM -400"USED,, WHAT IS DE/ DM STANDS FOR?

2283


hi friends,im an instrumentation and contol engg student,can u hlp me of suggsting barc written question paper,my id is roysuvaranjan@gmail.com, cel no.9563591747

2046


What is zero elevation and zero suppression?

2234


we have a s-5 simense plc having op7 .recently on op7 showing error 1.plc not present 2. DB error frequently. can u have any solution . please send me.

2657