Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why is it that bus reactors are not accompanied by a neutral
grounding reactor whereas a line shunt reactor is? PGCIL
does so.

Answer Posted / subbarayalu

In EHV Line, if there is single pole auto reclose used, during single phase fault, the faulty line may have arc current due to resonance which will disturb the auto reclose. Also, there will be transient recovery voltage. To compensate this effect we require Neutral Reactor in the EHV line. Whereas the same Auto Reclose condition will not be in Bus Reactor breaker. Hence, neutral grounding reactor is not required in Bus Reactor

Is This Answer Correct ?    16 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

please send 5yearje solved papers on my email himmatsinghnathawat@gmail.com

1977


Its possible to use 3core 2R of 240 sq.mm cable for 3phases & separely 50sq.mm 3core cable fully for Neutral for connection of PCC to MCC 3ph..4wire system?

2150


why do we put a transformer on soak before loading it

1192


How to select circuit breakers rating eg. if i select a circuit breakers of capacity 40 amps DC with operating voltage 28 volts and if i what to use same circuit breakers for 300 Volts DC application what is the current rating of this circuit breakers.

1770


I want d.g.set our company

1929


Why do power lines not short out when they fall into water?

2049


state the disadvantages of carbon filament???

2990


which fault is severe and why?between lll fault and lllg fault which fault is severe and y?

2548


How to design harmonic filter at the project stage without nowing the harmonics levels

2253


sent to a site and asked to explain how you would like a twenty seven flour building should be supplied with lighting and sockets plus a water boiler.

2015


what is the terminal voltage of dc series generator running at rated speed at no load?

7735


specify the inbuilt protections in DG

2117


1.what is mean by 8/20 micro sec waveshape

2283


why in the three pin plug all 3 pins are cutted ?

2069


what do w do when the output of generator is fluctuating?

2333