Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

75kw drive operated motor current fluctuation
from(85-130)ampere.current setting in drive
is 130amp.sometimes motor trip when current
limit cross 130amps.I change the drive. still
current fluctuate between 80-130amps but in
this time motor not trip,current setting in
drive is 130amps.where is the problem?

Answer Posted / mohit punjabi

the motor will not trip because as the user has change an old drive which was of 75 kw with new one so he has to set a parameter in new drive that when fluctated above 130 amps the drive should trip the motor without these parameter setting the new drive will not trip

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Who are the manufacturer for Nitrogen based Fire Protectio/explosion prevention for Oil Filled Transformers? India and international both?

1973


why magnetising curve not start with zero voltage?

2350


can any one tell me about the Extra low voltage systems?From where we give supply to these type of systems??

1967


my bachelors was done with EEE now i got admit in NU with CS as course. how to answer this qns 1) why u choose cs? 2) why u changed from eee to cs

1847


How do the synchronizing lamps indicate the correctness of phase sequence between existing and incoming alternators?

2235


Why neutral is not used in three phases dol starter

1995


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2524


what is meant by flywheel and its role in retardation test

2470


Where is the best place to mount  distribution panel in a house.

2146


how dia of wire and angles are calculated for overhead shielding wire to protect substation equipment from lightening strokes???

2084


PLEASE SEND THE PREVIOUS YEARS QUESTION PAPERS OF RRB JUNIOR ENGINEER-ELECTRICAL

1952


Post possible questions for Power Factor Panel FAT / SAT

1454


A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.

2010


if negative of DC supply used and positive is grounded through EGB, and if ELCB used in the system then is it sense the positive volatge and get tripped is it possible?

1953


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1979