Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why Urasil and Caffeine use for HPLC wavelength accuracy
calibration. which is most suitable, Why? other than these
which can be used?

Answer Posted / chemistry

Because uracil And Caffierne Shows The absorbance Range in
245nm And 340nm.

Is This Answer Correct ?    0 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How do we quantify crystaline and amarpous forms by using (NMR, XRD)spectroscopic techniques? Which any others instruments are useful for this quantification? explain

2437


We use Potassium Dichromate solution for the calibration of UV-Visible Spectrophotometer in UV region. My question is to calibrate visible region which solution could be used in photometric accuracy

1963


WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?

2624


Why acetonitrile and water are used as extraction solvent when analysis melamine? I thought they are miscible and won't be able to separate...

1751


What is the use of tlc and hplc? And when and where use?

1211


Why dissolution test is not performed in all of the products

2578


Ph meter can show more than 14 ph reading? Why ph range in between 1 to 14 only?

795


we can use expired sample for validation and analyst qualification?

861


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3723


Ratio of Water and Acetonitrile(diluent) is not recommended to use in cleaning method validation,why?

3020


if content uniformity passing but dissolution varrying then what is next step?

936


iam usig ph buffers merk. manually how to prepare ?

2325


how many types of balance calibration test?

2354


what is mean by extactable and leachable study?

1224


UV and PDA detector, which have less signal to noise ratio?

1177