Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we are used 4,7,9,2 buffers for the ph calibration

Answer Posted / arash babakhanian

pH is determined from this equation in the pH meter

pH = [(Eobs-K)/0.059]n

Eobs= observed potential
K= constant paramere
0.059=slope

constant parameters k and 0.059 should be calibrated. In
fact two acidic buffers and two alkalic buffers are used to
fix slope and K constant . In this case, the relation
between Eobs and pH is analyticaly change

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is mean by 40 in the dissolution basket mesh size?

780


what is the different in Total ash, sulphated ash, acid insoluble ash, alcoholic or non alcoholic ash?

9988


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3532


How can I develope method of dissolution by HPLC OR UV

2401


What is the acceptance criteria for moisture balance when calibrated with sodium sulfate

2034


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3659


what parameters we will consider while developing a HPLC method and how we confirm our HPLC method is valid?

3674


WHAT IS THE PURPOSE WE USE HCL, CHOPPER, BURNER, MONOCHROMATOR in AAS? PLEASE EXPLAIN BRIEFLY

2603


What is delay volume?

1372


What is the accrptance criteria in RSD for RS method precision on basis of impurity percentages?

817


What is column in chromatography?

2232


for inorganic molecules require to do RS, Assay and disso?

728


Why only Copper standard is used to calibrate Atomic Absorption spectrophotometer?

2720


why we use Dichlorobenzene.nitrobezine.t-butyldi sulhate.for calibration of gc Head space

2260


Why dissolution test is not performed in all of the products

2530