How to calculate 47Liter H2 Gas cyilnder consumtion?
Cylinder inlet Pressure is 200bar and Discharge pressure
is 6.0bar. Flow is 100ml/min.For the above condition how
many days one cylinder can be used?
Answer Posted / vikash suthar
As per Boyls law PV= Constant.
So, inside pressure1 and volume1 is 200bar and 47 liter,and
out side pressure2 is 6 bar ,volume2 to get at 6 bar.
p1v1=p2v2
200x47=6 x v2.
v2=200x47/6=1566 ltr volume.
now out side flow at 6 bar pressure is 100ml/min=6 lt/hr.
now if 6ltr passesin one hour then 1566ltr in how much hour.
so,261 hrs will be taken to empty the cylinder.
and that is 10.8 days.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
-/5A. What is the meaning and limitations of this in energy meter constant. It is a 3 phase LT Energy Meter. If this Energy Meter is connected through a CT of ratio 200/5 Amps, then what is the multiplying constant and how its will be calculated.
sir ,iam in dem urgent need of HPCL Paper of Instrumentation Branch plz send me at your earliest convenience at ujjwal_sharma1983@yahoo.com
Explain signal isolator
is motorized valve closed when power shutoff?
Full form of KKS when use DCS.
sir,would you please send me the Hindustan petroleum corporation limited papers(HPCL).my e-mail ID is ujjwal_sharma1983@yahoo.com
What is Span Error
What you mean by multi stage control vavles?
Im having problems with interfase betwen SPI v7.0 and SPPID v5.05. Previous versions of Intools shoul be fixed with SPPIDproj.ocx file. It was necessary to replace this file with one that allows the connection between different versions of SPPID. It is necessary in the current version to do the same?Thanks
Which products are available in the Mass Systemswitch and System Manager AC range?
What are different types of orifice plates?
what is a vortex flow meter,mass flow meter and electromagnetic flow meter.particular use of this.means in which condition particular meter is used.
where proximity sensor installed on tank in loading arm application
What is solenoid valve? Where it is used?
what is use of communication wire in multipare cable(oil and gas field), why this communication wire not used in single pair cable?