Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

there is a power transformer 66/11kV in delta-delta
connection has 5 feeder coming out from the secondary side.
One of the feeder in it normally loaded (loaded than other
feeder)and this feeder usually trips with double OCR causing
the bank transformer to trip. Now if the load of this feeder
is put on other transformer then that no problems occurs on
that transformer or the load. However normally all the
test(IR, PI, short ckt, open ckt,grounding test and other )
has been conducted for this but evertything transformer.....
I am not geting what is the actual problem...

Answer Posted / parin patel

This thing happened dew to %Z of transformer.lesser the %Z current supplied by transformer will be more.
example:- there are two transformer
transformer 1: 66/11 kv,%Z= 5% ,15 kVA
transformer 2: 66/11 kv,%Z= 7%, 15kVA
If load is constant(same), current supplied by transformer 1 at 11 kv is more than current supplied by transformer 2 at 11 kv.

In your case ,you have to check the value of feeder current when it's supplied by two different transformer.in both case it might be different.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Please explain me abt PQ diagaram in the power sector.

2408


what is the difference between linear choke and suction choke?

2717


What is Control & Relay Panel? And Remote Control Center?

2214


where lt & ht capacitor used

2220


As a electrical engineer.. what are the basic norms should follow in transformer oil testing.. 1.What is the Electrode type? 2.How long time you will give for oil testing?

3633


what is solkor relay and which condition it will act?

3352


Whether it is possible to measure energy at the input of rectifier transformer (12 pulse with very high odd harmonics)

1899


How to calculate size of HT breaker with the help of Amp (current)? Please provide answers with examples.

2324


what happen if the parallel generator phase angle shift by 1 degree in manual mode

2044


what's the difference between 'shaft power demand' and 'BHP' , when we consider electrical load list.

1513


in basic 2 phase will short means tripping the power but spot welding 2 phase shorting but not tripping it will welded why.....(Q)

1946


If you have an earth with pilecap then your resistance is really low. why and how?

1990


how to decide the panel size like MDB ,SMDB PANEL SIZES

7347


How To Convert Apparent Into Real Power Without Knowing Reactive Power?

1775


What is the difference IN MCCB's between thermal magnetic and electronic tripping system ?

2035