Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

difference between DCS @ SCADA system?
and how can use in field

Answer Posted / deepan.p

DCS-ITS A CONTROLLER IT HAS PROCESSORS AND MODULE LIKE ANALOG
I/O,DIGITAL I/O,RTD,T/C,VALVE POSITION MODULE ETC
WE CAN CONTROL AND MONITER THE PROCESS.
SCADA- IT ONLY A USED TO MONITOR THE PROCESS &WE CAN CREATE
THE GRAPHICS OF PROCESS SOMETHING.ITS NOT USED ALONE.IT JUST
CONNECTED WITH PLC ETC.
DCS IT SELF CONTAINS SCADA SOFTWARE

Is This Answer Correct ?    10 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

2174


Name different types of bourdon tubes.

1134


how many types of viberation transmitter and how to calibrate and where use of vibration transmitter

2138


in mass flow meter what is drive friquancy ?

2095


how to convert cubic metre per hour to newton cubic metre per hour

2006


hello friends, can you please send me the model paper or question paper to be prepared for hpcl examinations????????? You can mail me at rahim_here@yahoo.com waiting for your reply........... help me .. plz.....

2605


Make a ladder diagram on LSL valve will close, on PSL valve will open and start the motor

2141


Draw a P& ID showing – orifice flange, plate, dp transmitter, isolation & bypass valves and tubing.

1931


To become an Instrument DESIGN engineer, is there any softwares or training to become Instrument Design engineer, plz suggest me, Iam very much interested in designing.

3471


Exothermic reaction./ endothermic reaction

2034


what is the procedure of O2 sensor(ABB) calibration?

2187


how do calibrate the valves.. with clear manual

2089


how to calibrate load cell

2839


Can u tell me the principle of the tc,rtd,level switch,pressure switch ,transmitter(pr flow level temp.),vibration...plz

2055


WHAT IS TMXT IN TEMPERATURE FOUNDATION FIELDBUS.