difference between DCS @ SCADA system?
and how can use in field
Answer Posted / deepan.p
DCS-ITS A CONTROLLER IT HAS PROCESSORS AND MODULE LIKE ANALOG
I/O,DIGITAL I/O,RTD,T/C,VALVE POSITION MODULE ETC
WE CAN CONTROL AND MONITER THE PROCESS.
SCADA- IT ONLY A USED TO MONITOR THE PROCESS &WE CAN CREATE
THE GRAPHICS OF PROCESS SOMETHING.ITS NOT USED ALONE.IT JUST
CONNECTED WITH PLC ETC.
DCS IT SELF CONTAINS SCADA SOFTWARE
| Is This Answer Correct ? | 10 Yes | 0 No |
Post New Answer View All Answers
Why boiler chimney area oxyden sensor fixing?
What is feed factor and its Importance in cement industry? How we can solve feed factor?.
centrifugal compressor interlock? Tell me the parameter at which compressor will trip
What is profibus?
Gas equation
What is instrumentation instrumentation engineering?
sir,would you please send me the Hindustan petroleum corporation limited papers(HPCL).my e-mail ID is ujjwal_sharma1983@yahoo.com
in mass flow meter what is drive friquancy ?
how many type of plug are used in pneumatic control valve,name them.
we are using centum vp as monitoring with Dell precision work station T3600 but some times PC(s) are restarted automatically . how we can solve this problem? thanks
what are the documents(Construction point of view for a process plant) submitted by contactor initially entering in to new site for client?
Area classification, Equipments, Gas groups, temperature classification, Ingress protection, Fire Extinguishers.
Hi Friends , i need one urgent help , i am preparing for M.tech entrance examination , i need some obejective questions related to instrumentation field. where can i get those ? can anyone help me pls ?
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
How to Calibrate Level Switch in field