A 3 phase motor, 440 voltage, induction motor. If we take
out rotor from motor and if we give supply 440 volt to
stator then what happens?????
Answer Posted / saravanan
stator winding gets heat for long time supply... its not
get burnt. Actually the winding value i mean ohms value
gets low...
But in a rotating condition of rotor,at that time can we
give supply to statorr? what will happen?
please reply to my mail sarvan2387@yahoo.com
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Show the schematic arrangement of diesel power station layout and give its principle of operation.
How to do cable sizing calculation for 750 A Neutral Earthing resistor for 33kv. the 33kv cable going to swbd. is 630mm2 3 runs.
What happens when two positively charged material is placed together?
In siemens PLC, why do we want to move the data ?
How harmonic block test are conducted on relays ( Siemens,Areva ect )power transformer using omicron kit?
how to decide the panel size like MDB ,SMDB PANEL SIZES
pre arcing time of ehv breaker
What is tranformer differtial?
How to confirm the Phase shifting Transformer VECTOR GROUP relation , as below ZNy11.45d10.45-ZNYy0.15d11.15
what is an unbalance in acircuit? in a three phase 3wire circuit how an unbalance will come? in a three phase four wire system how an un balance is coming?
What is the role of feedback in a closed loop control system?
sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.
We have received supplies of the ordered material. payments against the supplies also released. Where ST paid 4% against form C. Meanwhile it has been observed that 25% of material supplied was defective. Please suggest whether the issuance of C form from our side would be stopped till settlement of liabilities.
what is Fault level? why it is calculated? how will u decide same for our plant?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?