Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why it is necessary to short and ground of a current
transformer secondary side?

Answer Posted / k.prakashchandra

Shorting is done ,when the ct is not in use or in case of
spare ct, to prevent development of high voltage in
secondary.Grounding is done to remove the influence of high
primary voltage due to capacitance between primary and
secondary, and insulation failure.

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What will happen if we on 200kvr capacitor bank(11kv in bus)If there is low load on transformer (1.5 mva 33/11 kv)

1570


How to calculate or formula to calculate rhe power in 2 phase system ??

1513


What is the theoretical reason for the size of a zig zag grounding transformer to be 1.732 times less than that of a wye-delta grounding transformer used for the same application?

2285


how to calculate fault level?

2286


WHY CBCT USE ONLY IN Y PHASE NOT OTHER PHASES

2117


If Neutral Grounding Resistor (GR) failed/shorted. Is it repairable.

1635


is there any device that works properly accept relay, it may be fuse but if i want fuse of 33kv 300 amp it is avaliable, pls give me details

2000


1.why are not using acb 33kv ht side? is there any problem 2.what is difference between acb,vcb,sf6 breackers? 3.what is the function of invertor and convertor in ups?

2149


what the Microsoft .NET framework is?

2009


why we have and use 3 phase not 2 or 4 or other in power system?

2125


WHAT IS SUBSTATION & ACCORDING TO VOLTAGE HT,EHT SUBSTATION EXPLAIN IT

3170


sir pls tell me . our ct specifications are 120/5 ,2 core , 0.2 and 5p10 class , 30va and 30va buden. insted of 30 va i want use 15 va. can i use?

1516


What is advantages of VSCF wind electrical system?

2334


How do apply electrical 'c'license......pls advice

1714


What Normal(Tangent) towers and Tension(Cut-point) Towers?

6223