Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

whenewher three phase supply is given to induction motors
revolving/rotating field is created & rotor rotates.When
the three phase supply is given to three phase transformer
then revolving,/rotating field is created or not? if not
why?

Answer Posted / hussaini

Brother, its not about three
phase or two phase .... Its
about number of windings....
in three phase induction
motor three windings are
saperated by 120 degree a
part and wound on the stater
in such a way that whenever
a supply is given to these
winding produce a rotating
magnetic field... but in the
case of transformer's there
are two winding connected
parallely each on opposite
limb so e.m.f induce mutualy
to secondary winding ....
Simple, thts it

Is This Answer Correct ?    9 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why auxiliary transformers are not connected in parallel in primary stations?

1432


What are the difference between CT/PT operated Meter and RRAMR Meter for HT/LT application?

2609


why high speed tripping relay will be used in tripping circuit why not normal relay

1371


what happend to DC shunt motor if its field winding insulation becomes slightly weak? will that motor can run on full load or not explain in detail. thanks

1648


what is the electrical?

2115


does a DG set has low fault level as compared to that of a transformer.If yes then why.

1991


what is the difference between megger and earth resister ??

1816


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2131


What is the difference between acs 550 & acs 850

5810


What is the rating factor for copper cable ( Specific value according to the type of laying ) & the voltage drop?

1848


along with technical test papers

1609


What is fault clearing time for Current Limiting Moulded Case Circuit Breaker?.

1785


for 5KW resistive load can anyone please suggest me whether to go for UPS/Inverter or Generator depending upon cost calulations

2090


different aspects of voltage stability

2067


Define bibo stability.

1082