How to find quantity of cement mortar?
I want to know the req quantity of cement for plastering 300
sft in final coat with 12 mm. Any math involved? Plz help
Answer Posted / sudiptodas
its simple
1st step to fined the volume of mortar
as per question
300 sft=27.28m*m
thickness of plaster= 12mm
so volume of plaster= 27.28*.012=.3336m3
this is wet volume.to transfer in to wet
.3336*1.54=.514
this is your total mortar
conceder 1:3 mix
so cement= .514/4=.128= 3.7 bags
sand .128*3=.384m3
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
is there any codal provision for soil cousion over the Hume pipe of Dia 1.2 m.
Bernaullis theorem deals with the law of conservation of mass momentum energy none
In foundation design, while we do the base pressure check, we normally check if the attained pressure value is less than the GROSS BEARING CAPACITY of the soil which is the sum of net bearing capacity of soil and the overburden pressure. Actually, the overburden pressure acts against the net bearing capacity of the soil and I feel that we are actually increasing the bearing capacity value and doing the check. I feel that this is NOT right. Please clarify on this.
For Wet Mix Mecadam design what is Optimum moisture content
what is the use of beam end forces while using a staad ? wha they are show
how to identify the failure of building by expansive soils
What is the force exerted by the tacoma narrows bridge?
what is education Cess.
What is the value of live load that should be incorporated in design of locker room and cash vault room while designing a building for commercial bank?
What is Heavy Concrete & Normal Concrete
Wat is meant by Aecron brick?
What is meant by a context menu in a cad software?
A 16 pile group, consisting of diameter concrete piles, were cast in situ in a clayey soil whose unconfined compressive strength is 1100 psf. Each pile is 60 ft long and the pile spacing is 2.5 times the pile diameter.The water table is at the ground surface and saturated unit weight of the clay is 118 lb/cu.ft. using a factor of safety 3 and a reduction factor =0.45, compute the allowable capacity of the piles acting as individuals
What is the cost of formwork for columns/beams/rcc walls also what is the cost of shuttering for roof slab at height of 25 feet
All aptitude question of Bechtel