If i have two 3000 kW motors and the whole facility requires
a 10 MVA transformer.
What would be better installing two 5 MVA transformers(one
for 1 motor ) or just a single 10 MVA transformer for both
of them.
Give reasons for your answer.
Answer Posted / pandi
3000KW MOTOR 8MVA TRANSFORMER IS SUFFICIENT AND U CAN
PREFER 8MVA TRANSFORMER WITH TWO SECONDARY
WINDING(STAR,DELTA)IT WILL REDUCE UR NOISE AND HARMONICS ALSO
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
Which is the oldest hydropower plant in india?
Define piezo-electric effect?
prove that power consumed in 3 phase delta system is 3 times as compared to 3 phase star system
After synchronization with grid what is the demand value QKVAR and how we will maintain that?
What is the differance between 2 dc motors of armature voltage 660 v and 440 v?
What is zero of the system?
when it is possible kvrah lead & fundamental kwh be equal in electonic trivector meters (3 ph)
how many joints are allowed in underground HT cable of 1 KM
how to electronic energy metter failed in electomagnectic fild passing in the metter and which thing to defect more on metter.
why are distributed windings generally used in alternators?
Is MEN and RCD related to each other ?? IF yes then how??
how does WTI work ?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
What is the difference between electronic regulator and ordinary electrical rheostat regulator for fans?