why Transformer and DG rating capacity is in KVA
Answer Posted / g a reddy, essar steels ltd, v
The term power factor is related to load. It is not related to Generator and Transformer. I mean Power factor angle will not vary with out load.(cos of the angle between voltage and current.) This will vary depends on type of load.I can say capacitive loads will inject the reactive powers to line and inductive loads will draw reactive power(KVAR) from the line to develop a magnetic field in the windings.Active power is used to Drive the load(KW).
KVA= sqrt of(kw2+kvar2)
And also we can say Transformer and Generators Losses will depends on Voltage and current. So Ratings of these are mentioned in VA.
Is This Answer Correct ? | 5 Yes | 1 No |
Post New Answer View All Answers
WHAT IS DIFFERENCE BETWEEN MANUAL CONTROL AND MAGNETIC CONTROL AND STATE ITS ADVANTAGE /DISADVANTAGE
In control room of our one plant there is a continuously the incoming power goes to PC is vary,means in stabilizer it continuously indicate from high input to low and low input to high. what is the reason and its solution.
Saving in copper achieved by converting a 2 winding transformer in to an auto transformer is determined by A voltage transformation ratio B load on secondary C quality of core material D size of transformer core
sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance
What is the reason behind current flow(20 A) in amain earth cable of an SMDB? Is cuurent flow(45A etc) through a neutral cable acceptable?
What are locations arc protection relay is fixed.
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
defult setting in p220 micom motor proction relay for 11kv,640kw,f.l.a.-40a,1440rpm ht motor?
define displacement & magnitude ?
Why in metering Ct for ammeters ct secondary side is grounded for each Ct but not in case of CBCT (Core balance current transformer)..kindly some1 highlights the reason..is it because net flux is zero?
how to find the Motor,s insulation Power?
what is difference between 2 pole structure and 4 pole structure in transformer yard
what is the current density of copper & alluminium.
What is Servo Ventilated Motor?
What are the advantages of vscf wind electrical system?