Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How you will select column for HPLC development depends on
nature of compound and how it will work explain in brief?

Answer Posted / muzammil thange

Compounds should be seperated on "like likes like basis" ie polar compounds should be separated on polar columns and vice versa. Polar compounds when analysed on C-18 should be treated with modifiers to act like non-polar or neutral compounds.

Is This Answer Correct ?    4 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the Formula for coreletion coefficient in plhplc calibration

1831


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1596


could negative ions be produced by bombardment process in mass spectrometry?

1781


In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )

3486


[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

791


Why do we use KMnO4 in the test of control of obsorbance ? and why do we take specific quantity i.e 57-63mg?

2833


In rs method development when we are going area normalization method to dilute standard method?

1524


What is the difference between purge septum flow and column flow in gas chromatography?

2586


What is the difference between spectro meter and spectro photo meter?

11514


How require to develop GC method? how to select diluent, GAS, column selection and other chromatographic conditions?

734


what is biorelivent dissolution media?

807


How to determine the EDTA content by potentiometry titration in Ceftriaxine sodium

2546


i want model written test paper for the post of analyst in IOCL(indian oil corporation ltd) any one pls help me

2734


Why irmoisture balance is used for corrugated box moisture testing

2404


how much mass should be there in volumetric flask while in preparation of sample for assay? 

2580