Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is an infinite bus bar?

Answer Posted / puspita panigrahi

The source or supply lines with non-variable voltage and
frequency are called infinite bus-bars. The source lines are
said to have zero source impedance and infinite rotational
inertia.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how balanced in star delta connection ?

2036


in parallel operation of power transformer why the distance between power transformer and capacitor bank feeder is necessary to know

1756


what is submersible pump?what is different between motor and sub motor?

1995


What is making & breaking current ???

1452


Why we find the sensitivity for the CT's to check?

1805


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1731


What Maximam Gap Taibaar & Bush

2251


what is transient enclosure vltage , very fast transients, very fast transient over voltages

2089


If we are given a 10 amp cable type and asked to calculate the number of cores used and the thickness of the cable, how do we do it?? please help...urgent!! i hope the question is clear enough!!

1755


i need list of swg(standard wire guage) or area of conductor v/s current carrying capacity of conductor copper & alluminium...

1767


how we will deside the high voltage value

1910


What is the purpose of stablization resistor in high impedance bus bar protection

1945


What is the previous name of Cox's Bazar

1914


what is the maintaining Cf in UPS.

2285


A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram

2766