How we can do the linearity test for Bently Naveda
Vibration Probe?

Answer Posted / ahmed sabry

first, we have 3 main types of Bently vibration probes:
1 - Proximity probe
2 - Accelerometer probe
3 - Key phasor probe

For proximity probe, we have 2 types:
1 - displacement probe for axial forces measurement.
2 - velocity probe for radial forces measurement.

Both tyes of probes are calibrated using a suitable calibration kit supplied by the vendor, the calibration kit simulate the shaft vibration and can be used to check/adjust the probe and the monitor.

I have a practical experience with 3300 system which give the output through "proxomiter" from terminals output & ground - for normal case it has to give "-10 vdc" and we have 200 mv for every 1 mil diplacement.

This is an example of used calibration kit:

http://www.ge-mcs.com/download/sensors-and-transducers/141580.pdf

==========

If we need to Check/calibrate the rest of the vibration loop (monitor check), We will need a function generator & multimeter.

For the monitor we will inject in the Monitor card by the function generator a combination voltage of -7 dc voltage with AC voltage with suitable freq.(follow the manual to specify the values of AC, DC and freq.).

For axial vibration monitor we will vary the DC amplitude and check the results on the monitor.

For radial vibration monitor we will vary the AC amplitude and check the results on the monitor.

Best of luck

Ahmed Sabry
Instrumentation & Control Engineer
Mob: +2 0122 1367310

Is This Answer Correct ?    18 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to calibrate steam control valve in steam turbine

2909


sir, give me placement papers and interview quistion of birla group company of copper.

2483


Hook up resistance decade box to temp.transmitter.

1802


Describe the typical instrumentation used in monitoring the performance of a shell and tube heat exchanger.

1649


installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,

1752






use of split range ? where it is used ? in which control loop it is used ?

1573


what is the difference between Cv and air consumption? why the customer needs Air consumption details?

1619


hi friends,im an instrumentation and contol engg student,can u hlp me of suggsting barc written question paper,my id is roysuvaranjan@gmail.com, cel no.9563591747

1657


while am calibrating Drager polytron 2IR flame gas detector occured non zero status.how can i get zero status?

1831


1.what is controller proportional gain 2.what is the controller intergral action time. 3.A proportional plus derivative controller that has a proportional band of 20% and a derivative action time of 0.1 minutes. Construct the shape of the output waveform for the triangular input if the input rises and falls at the rate of 4 units per minute.

2321


we are using centum vp as monitoring with Dell precision work station T3600 but some times PC(s) are restarted automatically . how we can solve this problem? thanks

1854


How does a single acting, spring return ball valve actually work? Does it require continuous air supply? 

1766


Hi Friends , i need one urgent help , i am preparing for M.tech entrance examination , i need some obejective questions related to instrumentation field. where can i get those ? can anyone help me pls ?

1589


3. Differentiate between ultrasonic flowmeter and radar type flow meter.

2541


Can u tell me the principle of the tc,rtd,level switch,pressure switch ,transmitter(pr flow level temp.),vibration...plz

1616