Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the need of ISOLATION Transformer?

Answer Posted / lakshmi

isolation transformer is a 1:1 transformer. its basic
principle is same as that of ordinary transformer. only the
difference is it can`t step up or step down the voltage. it
provides only isolation between primary and secondary.
strikly speaking that isolation transformer provides more
safety for electrically operated equipment like hand
drilling machines, electric shaving kit etc.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

There are Two questions about Steam Turbine Generator... What is HRSG bypass of LP, HP used for in power generation? In particualar, in the event that fault of HP bypass, there would be STG TRIP in operation but none on the LP bypass fault...what's the reason ?

2261


operation of diesel generator

1969


how can i get an electrical c-certificate?

2176


why can we use cosine wave instead of sine in ac supply as both have same rms vale and ripple factor

2509


Can anyone tell the proper diagram of star delta starter????

1872


what is the affect of earth's magnetic field on the frequency used in aircraft???

1951


i have flexible wire. size of conductors is 0.190 mm & no.of conductors are 48. then size of wire comes 1.37 sqmm instead of 1.5 sqmm . the what is tolerance for this size.

1745


Dear Respected sir how to test ABB REX521 protection relay by relay tester.

2690


what are the advantages disadvantages of connecting high voltage block( 1:1 transformers) transformers between the turbo generators and busbars.

2045


what is the formula for efficiency of francis turbine and generator for hydropower? what is best way to select francis turbine and generator?

2448


What are the criteria shall be considers for sizing Fuse and MCB? If the rated current is 10Amps what should be the fuse size / MCB Size?

1563


we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain

2170


How to do bus bar short circuit calculation for 230KV/11kv, 60 MVA Substation?

4681


please give me all the Alarm .Trip ,Safety Relays & Conditions of UPS Systems mail me on ashokbabunhce@gmail.com

1731


what is per unit calculation?looking for simple and strong explanation thk u

2825