Why only negative 24 vdc supply give in vibration measuring
system.

Answer Posted / mohammed abbas

Because it is NPN tansistor during the initail days when
this was inveted by bently the cost of NPN transiator was
less. then they started use NPN transiator for the
vibration propbe, due to this we will give negative 24vdc
supply

Is This Answer Correct ?    5 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is intrinsic safety mean.

1552


Why the ammonia and Nitric Acid level indicators is with millimeter ? and What is the conversion form millimeters that level indicator indicate to weight ?

1313


If fire would be inside the plant which fire detector is to detected the fire.

1168


Can Any body tell me how to check Modbus Settings in ER300N L&T trivector meter?

2172


Explain how thw analog to digital converter works with the circuit diagram

2278






Hello to all....I am an Instrumentation Graduate and i am passed out in this year only.. I am unable to find the job in my core instrumentation.. so any boby tell me how to and where to search the job....please...and also tell me i there are any courses offered in the instrumentation stream so i can do it... you can send your suggestions to my mail-id i.e Ganesh20084u@gmail.com ... please..

1579


Senior engineer's please help me, what is Loop Checking and Loop test? and write difference also? soon urgent

1682


Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer

4270


hi sir yhis is zahid ali i am preparing for the jspl at oct.4.please send me the recently updated sample paper.

1802


In Safe Guarding test what means by "Failed to Danger" ?

1739


can you provide me full detail about instrumentation in ONGC??

1844


why we use 3 wire rtd direct wiring for temperature measurement instead of temperature transmitter like bearing temperature

1476


what is function of switch, and how is it work, explain with difination

1905


Describe the typical instrumentation used in monitoring the performance of a shell and tube heat exchanger.

1649


Why use ball valves on Gas pipelines instead of gate & or globe valves...means basic diffrence or use of these valves..how designers knows this type of valve with rating is required...

1950