what is the Difference Between Domain and Station?
Answer Posted / praven kumar m
In Yokogawa System if the no. of station is 56 or less than
56 the domain no, will be domain#1. If it exceeds more than
56 stations then we have to consider 2 domains (i.e.,
domain#1 and domain#2)
For eg. if there are 2 units, and the first unit consists
of 65 stations. in this case the first 56 stations will be
considered as domain#1 and station nos. from 57 to 65 will
be considered as domain#2. The 2nd unit will be considered
as domain#3.
| Is This Answer Correct ? | 1 Yes | 4 No |
Post New Answer View All Answers
which processor is used in dcs.
principle of dead weight tester ?
what is the difference between magnetic flow meter and mass flowmeter
What is instrumentation technologists and mechanics?
What is the difference between uv and ir scanners? and what is the workig principle of both
A flange is used for instrument connection for a system with a design temperature of 316C (600F) and a design pressure of 1000 kPa (145 psi). What is the class rating of the flange to be used for this application? Explain your answer
can anyone tell me about the basic concepts to consider before to start a PLC panel wiring
in valve is constructed as per SME B 16.34, then which standard is used for fire testing of valve?.
What are different types of cable?
What is the PLC configuration in Cement industry?
hi my name is rakesh patel i just complited my be in instrumentation & control now i am going to working as a validation engineer in a poject department so what is a scope in a future as a validation engginer ? what line is good for me can any bady give me complete solution please? your regard rakesh patel
1)How many tpes of vibration probe and how many tpyes of vibration. 2)how we can calibrate a vibration probe with tk3 3)what is RMS value in vibration measuring application and how we calculate it.
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
Explain Gas Turbine startup and shutdown sequences
HI, can anybody give details about GAS TREATMENT PLANT CONSTRUCTION,as INSTRUMENTATION ENGINEER what are the responsibilites.what are the instruments mainly instrumentation engineer will deal with