what is the funda of earthing? Explain breifly about
earthing?
Answer Posted / s. prakashmurthy
The earth connection improves service continuity and avoids
damage to equipment and danger to human life.
The object of an earthing system is to provide as nearly as
possible a surface under and around a station a uniform
potential and as nearly zero or absolute earth potential as
possible.In general, all parts of apparatus other than live
parts,shall be at earth potential which is always at a zero
potential.
( This information is referred from IS:3043 - 1987 for the
benefit of readers ).
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
will there be any problem by recovering slip from single phase induction motors?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Please clarify 1. Icw: rated short circuit working withstand capacity 2. Icu: Rated ultimate breaking capacity 3. Ics: Rated service short circut withstand capacity 4. other specification of ACB
how to test power transformer.YNd11
If ROC does not lies inside unit circle,then ? a) Fourier transform converges b) Z transform converges c) Hatly transform converges d) Colpit Transform converges.
what is the effect of higher value of GD???
why effective resistance should be more than static resistance in transmission line?
I have been using an 600VA with 0.6 p.f UPS with my desktop which has 450W power supply unit. Can anyone explain how can this happen . Because the output of the UPS is 360W (600*0.6) (<450W)
Draw torque - speed curve and load curve of induction motor? mark operating point ?
where does 22kv line starts
how the CT and PT is connected in the circuit during testing of transformer explain with diagram
If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a camp site.?
A 1F capacitor is charged to 100V initially. A 1H inductor is connected accros the capacitor througha a switch. The current in the circiut when the switch is closed is____
explain transformer ct connection?
What are the operation carried out in thermal power station?