Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to calculate 1:2:4 ratio concrete cement, sand, metal
and water please give me brief calculation

Answer Posted / shahnawaz

calculation for 1:2:4(M15)
take 50%extra for shrinkage/wastage
1+.5=1.5/1+2+4=.214
now, in 1 bag of cement having qty =.0347cum
so,.214/.0347=6.16 no of bags.
for sand,.214x2=.428 cum
for aggregate,.214x4=.856cum
for cft just x35.31

Is This Answer Correct ?    7 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if a pipe those configuration (ASTM c 76 class b 450mm dia 2500mm length) fixing for water course those lining of water is 7000 running meter. my question is that if 8 joints of pipe ls leakage and we have not permission to stop the water so which treatment we apply on joint in that in condition.

2094


Any strength is a stress but any stress is not strength

1741


how i can tak Quantity of mortar in block work

2339


225 mm thick RCC slab, how many ton load slab can carry? for example if 33 ton truck loaded with soil, truck having 6 wheels. slab can take load or not? grade of concrete is M35 and slab design Fe500, slab desing one way slab.

3305


according to the painting co efficient, we should take the one side of doors (or) windows or both sides?

1726


Design an underground tank of internal dimensions 6m x 3m x 3m. The soil surrounding the tank always remains dry. The tank shall be provided with a roof slab. The soil weighs 16000 N/m3 having an angle of repose of 30.

2066


how can can column be corrected when the design is not safe ? is the increasing the clearcover a solution?

1568


rate analysis hiring of generator 62.5 KVA

2145


If u want ur Ans.Of any Question so mail me skatiyar011@yahoo.in

1964


what is modular brick and it size

1666


in the earthquqke the profile of water on dam is parabolic or not

1911


What applicable rate of wct in bihar

1796


What is difference between engineering stress and true stress?

1113


how much cost of single coat 20mm thick plastering per sqre meter

1567


Explain what is 1/8 on the architect ruler denotes?

1117